Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acad Radiol ; 31(3): 956-965, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37648581

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the effect of compressed SENSE (CS) in clinical settings on scan time reduction and image quality. MATERIALS AND METHODS: Ninety-five magnetic resonance imaging (MRI) scans from different anatomical regions were acquired, consisting of a standard protocol sequence (SS) and sequence accelerated with CS. Anonymized paired sequences were randomly displayed and rated by six blinded subspecialty radiologists. Side-by-side evaluation on perceived sharpness, perceived signal-to-noise-ratio (SNR), lesion conspicuity, and artifacts were compared and scored on a five-point Likert scale, and individual image quality was evaluated on a four-point Likert scale. RESULTS: CS reduced overall scan time by 32% while maintaining acceptable MRI quality for all regions. The largest time savings were seen in the spine (mean = 68 seconds, 44% reduction) followed by the brain (mean = 86 seconds, 37% reduction). The sequence with maximum time savings was intracranial 3D-time-of-flight magnetic resonance angiography (202 seconds, 56% reduction). CS was mildly inferior to SS on perceived sharpness, perceived SNR, and lesion conspicuity (mean scores = 2.32-2.96, P < .001 [1: SS superior; 3: equivalent; 5: CS superior]). CS was equivalent to SS for joint and body scans on overall image quality (CS = 3.02-3.37, SS = 3.04-3.68, P > .05, [1: lowest quality and 4: highest quality]). The overall image quality of CS was slightly less for brain and spine scans (mean CS = 2.79-3.05, mean SS = 3.13-3.43, P = .021) but still diagnostic. Good overall clinical acceptance for CS (88%) was noted with full clinical acceptance for body scans (100%) and high acceptance for other regions (68%-95%). CONCLUSION: CS significantly reduced MR acquisition time while maintaining acceptable image quality. The implementation of CS may improve departmental workflows and enhance patient care.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/métodos , Razão Sinal-Ruído , Encéfalo/diagnóstico por imagem , Artefatos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...